QTc calculator (Bazett, Fridericia, Framingham)
Correct the QT interval for heart rate with three formulas, with torsades risk thresholds and a wide-QRS warning.
Formula
RR = 60 / HR (s)
Bazett = QT / √RR; Fridericia = QT / ∛RR; Framingham = QT + 154 × (1 − RR)
Bazett = QT / √RR; Fridericia = QT / ∛RR; Framingham = QT + 154 × (1 − RR)
Worked example
QT 440, HR 96 (RR 0.625): Bazett 557, Fridericia 515, Framingham 498 ms.
Assumptions
- QT measured in the lead with the longest clear T wave (often II or V5).
Limitations
- Bazett overcorrects at fast rates and undercorrects at slow rates.
- Atrial fibrillation: average several beats.
Related
References
- Drew BJ, Ackerman MJ, Funk M, et al. Prevention of torsade de pointes in hospital settings: a scientific statement from the AHA and ACCF. Circulation. 2010;121:1047-1060.
- Sagie A, Larson MG, Goldberg RJ, et al. An improved method for adjusting the QT interval for heart rate (the Framingham Heart Study). Am J Cardiol. 1992;70:797-801.
Calculators support education and clinical reasoning. They do not make treatment decisions. Results depend on the accuracy of the values entered and the assumptions listed.